Canon GM-1000 Spezifikationen Seite 119

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 140
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 118
CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
119
Parameter ID 28
Parameter
Name
Scan Angle of Raster Scan
Data Raster scan angle (Unit: degree × 10000)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This parameter is used to set the angle of raster scan (operation by command).
(See Explanation of Parameter ID = 26.)
Set the scan angle × 10000.
For ±5°, set 50000 (5 × 10000).
Related
Command
/Parameter
Cycle Time of Raster Scan (Parameter ID = 26)
Duty of Raster Scan (Parameter ID = 27)
Interval Time of Raster Scan (Parameter ID = 30)
Start Position of Raster Scan (Parameter ID = 31)
Parameter ID 30
Parameter
Name
Interval Time of Raster Scan
Data Raster scan Interval time (Unit: second × 100)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This parameter is used to set the Interval time of raster scan (operation by command).
(See Explanation of Parameter ID = 26.)
Set the wait time (sec) × 100.
For 0.1 sec, set 10 (0.1 × 100).
Related
Command
/Parameter
Cycle Time of Raster Scan (Parameter ID = 26)
Duty of Raster Scan (Parameter ID = 27)
Scan Angle of Raster Scan (Parameter ID = 28)
Start Position of Raster Scan (Parameter ID = 31)
CW
CCW
Raster Scan Interval Time
0
Scan Angle 
(-)
Raster Scan Interval Time
Scan Angle 
(+)
CW
CCW
Raster Scan Interval Time
0
Scan Angle 
(-)
Raster Scan Interval Time
Scan Angle 
(+)