Canon R-F10 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messen, Testen & Steuern Canon R-F10 herunter. User Manual / TSRD-500 - ampelos Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 60
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1
PRECAUTIONS
1. Avoid following environment for operation and storage:
1). Expose to direct sunlight or close to heat equipment.
2). Expose to humid, dusty or poorly ventilated room.
3). Close to chemical material, metal particles or explosive gas.
2. Safety precautions:
1). Operate the equipments strictly according to this manual.
2). Contact to authorized service agency, when there is a problem which can
not be fixed according to this manual.
3). Turn off the power switch or unplug the power plug, when smoke, strange
noise or unknown problem inside the equipments occurs.
4). Do not disassemble the equipments.
TSRD-500 DIGITAL REFRACTOR
Seitenansicht 0
1 2 3 4 5 6 ... 59 60

Inhaltsverzeichnis

Seite 1 - TSRD-500 DIGITAL REFRACTOR

1 PRECAUTIONS 1. Avoid following environment for operation and storage: 1). Expose to direct sunlight or close to heat equipment. 2). Expose

Seite 2

10 27. Cylinder 28. Spherical 29. P.D 30. 5D=5 degrees (Spherical axis);1D=1degree (cylinder axis) 31. ERR or OFF: Chart

Seite 3

11 5. LCD Monitor With Touch Control 5.1 Menu 5.1.1 Date/Time Press the big knob to adjust date and time as following: (1) Choose Y(year), and

Seite 4 - 3. Note for installation

125.2 Auxiliary 5.2.1 Pinhole Touch Pinhole→Confirm, press FunctionClose when all gets down. ※ Pinhole is using for testing the “Lazy eyes”. You

Seite 5 - 4. Main Body And Keyboard

135.2.3 red&&&&green filters Touch red&green filters→Confirm, press FunctionClose when all gets down. 5.2.4 0.50Dissociation prism 6△△△△BU10△△△△BU

Seite 6

145.2.5 Fixed cross cylinder Touch Fixed cross cylinder→Confirm, press Function Close when all gets down 5.2.6 Retinoscope Touch Retin

Seite 7

155.2.7 ± Cylinder Touch ± Cylinder→Confirm, press FunctionClose when all gets down ※In this function, it can change the degree of ○- prism into

Seite 8

165.4.1 5.4.2 50839 E 5.4.3 Newspaper

Seite 9

175.4.5 Color Blind

Seite 10

18 5.4.5 The eye 5.5 Help When you do not know how to use, touch Help key, and all the details that show you how to operate, how to test e

Seite 11 - 5.1 Menu

196. Control Digital Refractor and Chart Projector by Keyboard and Touch Panel 6.1 Controlled by Keyboard (1) Turn on the power (Digital Refractor,

Seite 12 - 5.2 Auxiliary

2PREFACE Welcome to choose SCIENCETERA DIGITAL REFRACTOR. Read this manual carefully and handle the equipments correctly, thus the equip

Seite 13

20(5) You can use both big knob and ○+ , ○- to control Spherical, cylinder and P.D. (6) ADD: near and far point test, and ADD will be the

Seite 14

21 6.2 Charts Function The function of touch panel: The touch panel is composed of three parts: ③Chart Area, ②Function Area and ①Display

Seite 15

22 6.3 Fixed Cross Cylinder Test for Single Eye Touch , ±0.50 (Digital Refractor) will automatically turn to the right aperture of Spherical, an

Seite 16

23 6.4 Simple Eye Test Touch , Digital Refractor will change to Axis, and chart projector will also be in the right position automatically.

Seite 17 - 5.4.5 Color Blind

246.5 Red and Green Filters Balance Test Touch , of chart projector will appear on the screen. In the Chart Area, whichever chart you touch,

Seite 18

256.6 Binocular Balance Test with Polarized Filters Touch , it will be in the right position automatically, and the polarizing filters will be 1

Seite 19 - Touch Panel

266.7 Duachrome Balance and Polarizing Filter Test Touch (of chart projector), it will be in the right position automatically, and the polarizin

Seite 20

27 6.8 Stereo Test with Polarizing Filters Touch (of chart projector), it will be in the right position automatically, and the polarizing filt

Seite 21

28 6.9 Phoria Test with Polaroid Filters Touch (of chart projector), it will be in the right position automatically, and the polarizing filter

Seite 22

29 6.10 Horizontal Aniseikonia Test with Polaroid Filters Touch (of chart projector), it will be in the right position automatically, and the

Seite 23

35.6 Return P19 6. Control Auto Vision Tester and Chart Projector by Keyboard and Touch Panel P20 6.1 Controlled by Keyboard P20 6.2Charts Function P

Seite 24

30 6.11 Vertical Aniseikonia Test with Polaroid Filters Touch (of chart projector), it will be in the right position automatically, and the pola

Seite 25

31 6.12 Phoria Test Touch (of chart projector), it will be in the right position automatically, and the red/green filters (of Digital Refract

Seite 26

32 6.13 Worth Four-dot Test Touch (of chart projector), it will be in the right position automatically, and the red/green filters (of Digital R

Seite 27

33 6.14 Auto Cross Cylinder Power Test Touch (of chart projector), it will be in the right position automatically, and ±0.25 will tu

Seite 28

346.15 Maddox Rod Test and Prism Lens Correction 7. CO-operation with other Auto Refractometer

Seite 29

35 Automatic transmission: Press AR after Auto refractometer finishing print, and all the information in Auto refractometer will automatically tran

Seite 30

36Caution: Each time you must turn off the instrument if you change the code on the IC board, or it would not be effective.

Seite 31

379 PIN RedBrownBlackBlackYellowWhiteRedBlueGreenRedWhiteYellowBlackBlackBrownGreenRedBlue3. How to connect the connector between 5PIN and 9 PIN.

Seite 32

387.2 Co-operation with HUVITZ MRK-3100 The way of HUVITZ auto refractometer connect with TSRD-500 DIGITAL REFRACTOR and CHART PROJECTOR. 1.

Seite 33

399 PIN RedBrownBlackBlackYellowWhiteRedBlueGreenRedWhiteYellowBlackBlackBrownGreenRedBlue3. How to connect the connector between 5PIN and 9 PIN.

Seite 34

43. Note for installation 1. Digital Refractor uses DC-12V voltage. Avoid connecting with AC. Before installing, the electricity of transformer mus

Seite 35

407.3 Co-operation with CHAROPS CRK-7000 The way of CHAROPS CRK-7000 auto refractometer connect with TSRD-500 DIGITAL REFRACTOR and CHART P

Seite 36

419 PIN RedBrownBlackBlackYellowWhiteRedBlueGreenRedWhiteYellowBlackBlackBrownGreenRedBlue3. How to connect the connector between 5PIN and 9 PIN.

Seite 37

427.4 Co-operation with GRAND SEIKO 2100 The way of GRAND SEIKO 2100 auto refractometer connect with TSRD-500 DIGITAL REFRACTOR and CHART

Seite 38

4325 PIN 5 PIN on IC Board 3. How to connect the connector between 5PIN and 25 PIN. DIGITAL REFRACTOR

Seite 39

447.5 Co-operation with GRAND SEIKO GRK-1 The way of GRAND SEIKO GRK-1 auto refractometer connect with TSRD-500 DIGITAL REFRACTOR and CHART P

Seite 40

4525 PIN 5 PIN on IC Board 3. How to connect the connector between 5PIN and 25 PIN. DIGITAL REFRACTOR

Seite 41

467.6 Co-operation with GRAND SEIKO 3100K The way of GRAND SEIKO 3100K auto refractometer connect with TSRD-500 DIGITAL REFRACTOR and CHART

Seite 42

4725 PIN 5 PIN on IC Board3. How to connect the connector between 5PIN and 25 PIN. DIGITAL REFRACTOR

Seite 43 - 5 PIN on IC Board

487.7 Co-operation with SHIN-NIPPON 9001K The way of SHIN-NIPPON9001K auto refractometer connect with TSRD-500 DIGITAL REFRACTOR and CHART PR

Seite 44

4925 PIN 5 PIN on IC Board3. How to connect the connector between 5PIN and 25 PIN. DIGITAL REFRACTOR

Seite 46

507.8 Co-operation with NIDEK AR-610 The way of NIDEK 610 auto refractometer connect with TSRD-500 DIGITAL REFRACTOR and CHART PROJECTOR. 1. The

Seite 47

51WhiteGreenBlack5 PIN on IC Board8 PINRedYellow 3. How to connect the connector between 5PIN and 8 PIN. DIGITAL REFRACTOR

Seite 48

527.9 Co-operation with NIDEK AR-310A The way of NIDEK AR-310A auto refractometer connect with TSRD-500 DIGITAL REFRACTOR and CHART PROJE

Seite 49

53WhiteGreenBlack5 PIN on IC Board8 PINRedYellow 3. How to connect the connector between 5PIN and 8 PIN. DIGITAL REFRACTOR

Seite 50

547.10 Co-operation with CANON R-F10 The way of CANON R-F10 auto refractometer connect with TSRD-500 DIGITAL REFRACTOR and CHART PROJECTOR

Seite 51

555 PIN on IC Board3. How to connect the connector between 5PIN and 25 PIN. DIGITAL REFRACTOR A

Seite 52

567.11 Co-operation with AXIS TSRK-1000 1. The MENU of AXIS TSRK-1000 should be setting as following: MODE AUTO IOC

Seite 53

572. If you would like connect with CHART PROJECTOR, eight codes on IC BOARD of CHART PROJECTOR as follows: 3. How to connect the

Seite 54

587. 12 Co-operation with PICHINA PRK-9000 The way of PICHINA PRK-9000 auto refractometer connect with TSRD-500 DIGITAL REFRACTOR and CHART PRO

Seite 55

59 7.13 Co-operation with CHINA-AT3000 The way of CHINA-AT300 auto refractometer connect with TSRD-500 DIGITAL REFRACTOR and CHART PROJECTOR.

Seite 56

6Fig 1 (1) Measuring windows: Patients look at the charts through these windows. (2) PD

Seite 57 - AXIS TSRK-1000

609 PIN RedBrownBlackBlackYellowWhiteRedBlueGreenRedWhiteYellowBlackBlackBrownGreenRedBlue3. How to connect the connector between 5PIN and 9 PIN. DIG

Seite 58

74.2 Keyboard 1. Power switch on/off for lamp & motor(chart projector and digital refractor): Keep pressing the switch for 2 second

Seite 59 - RS232C:

8 (8) ±cylinder (9) 1°5° (10) prism I/O,U/D (11) auto cross cylinder XA, XC 20.Cross cylinder

Seite 60

94.3 Monitor 1. To show AR’s statement. 2. The detail-explanation of AR 3. Charts in work 4. Adjust date and time 5. F

Kommentare zu diesen Handbüchern

Keine Kommentare