Projector User Commands
- 128 -
Revision Histor
y
/ Date Chan
g
es Revised b
y
A
pp
roved b
y
GET ERR
Error information inquiry
Format
GETERR
?ERR
Response
g:ERR=<Error ID:ID>
<Error ID:ID>
Errors supported by model
Error ID Meaning
SX50
SX6, SX60,
X600
SX7, X700 SX7 Mark II
NO_ERROR No error
ABNORMAL_TEMPERATUR Temperature error
FAULTY_LAMP Lamp error
FAULTY_LAMP_COVER Lamp cover error
FAULTY_COOLING_FAN Cooling fan error
FAULTY_POWER_SUPPLY
Power supply error
FAULTY_AK
AK error
-
FAULTY_ASC
ASC error
-
FAULTY_AF
AF error
-
FAULTY_POWER_ZOOM
Zoom error
-
FAULTY_POWER_FOCUS
Focus error
-
For details on other responses, refer to the "Error List".
Description
This command is used to inquire about the current error information.
(1) This inquiry can be made in any status provided that AC power is supplied to the projector.
For the "SX50," the remote mode must be established.
(2) Information when the warning LED of the projector is flashing can be obtained.
"NO_ERROR" is returned when the warning LED is not lighted.
Example
> GET ERR or ? ERR
< g:ERR=FAULTY_LAMP
* Commands are indicated by ">", and responses are indicated by "<".
Commands supported
This defines the environments that support the command (power supply state, input signal state).
SX50
01.00**
SX6
01.01**
SX60
01.01**
X600
01.01**
SX7
01.01**
X700
01.01**
SX7 Mark II
01.02**
O O O O O O O
Environment
This defines the environments that support the command (power supply state, input signal state).
Power Input Mode
Model
OFF ON PM
D-RGB A-RGB1 A-RGB2 COMP Video S-Video D-Video SCART None
Remote Local
Remarks
SX50 O O O O O O O O O - - O O x
SX6, SX60,
X600
OO O O OO O OOOOO O O
SX7, X700 O O O O O O O OOOOO O O
SX7 Mark II
OO O O OO O OOOOO O O
* If a state is not supported, "INVALID_MODE" is returned with the Err response.
* When the power supply state is in the process of switching, an "i:BUSY" reply may be sent.