Projector User Commands
- 193 -
Revision Histor
y
/ Date Chan
g
es Revised b
y
A
pp
roved b
y
RANGE HPIX/VPIX
Horizontal/vertical resolution setting range request
Format
Horizontal resolution setting range inquiry Vertical resolution setting range inquiry
RANGEHPIX RANGEVPIX
Response
r:HPIX=N, <Minimum setting value>, <Maximum setting value>
r:VPIX=N, <Minimum setting value>, <Maximum setting value>
For details on other responses, refer to the "Error List".
Description
This command is used to inquire about the ranges within which the horizontal and vertical
resolutions can be set.
(1) For models other than SX7 Mark II: Inquiry can be made when the projector is in both the remote mode
and power-on status at the same time.
For SX7 Mark II: Inquiry can be made whenever the projector is in the power-on status.
(2) A “busy” response is given while the zoom or focus lens is being driven.
(Refer to the ZCONTDRV command and FCONTDRV command.)
(3) It may not be possible to make this inquiry with some input signals.
(4) The horizontal and vertical resolutions can be set using the HPIX and VPIX commands, respectively.
Example
> RANGE VPIX
< r:VPIX=N, 0, 1000
* Commands are indicated by ">", and responses are indicated by "<".
Commands supported
This defines the environments that support the command (power supply state, input signal state).
SX50
01.00**
SX6
01.01**
SX60
01.01**
X600
01.01**
SX7
01.01**
X700
01.01**
SX7 Mark II
01.02**
O O O O O O O
Environment
This defines the environments that support the command (power supply state, input signal state).
Power Input Mode
Model
OFF ON PM
D-RGB A-RGB1 A-RGB2 COMP Video S-Video D-Video SCART None
Remote Local
Remarks
SX50 x O x O O O x x x - - x O x
SX6, SX60,
X600
x O x O O O x x x O x x O x
SX7, X700 x O x O O O x x x O x x O x
SX7 Mark II
x O x O O O x x x O x x O O
* If a state is not supported, "INVALID_MODE", "NOT_POWER_SUPPLIED" or “INVALID_SOURCE” is returned with the Err
response.
* If the necessary signals are not input, 'INVALID_SIGNAL (*****)' or 'NO_SIGNAL' is returned.
* When the power supply state is in the process of switching, an "i:BUSY" reply may be sent.