Canon SX 50 Bedienungsanleitung Seite 54

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 244
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 53
Projector User Commands
- 48 -
Revision Histor
y
/ Date Chan
g
es Revised b
y
A
pp
roved b
y
HPOS/VPOS
Horizontal/Vertical position adjustment
Format
HPOS=<Horizontal position:Number>
VPOS=<Vertical position:Number>
Parameter
<Horizontal position:Number>
VPOS=<Vertical position:Number>
The parameters which can be set at any given point in time can be obtained using the RANGE
command. For details, refer to the RANGE command.
Response
"i:OK" is returned if the parameter was set properly.
For details on other responses, refer to the "Error List".
Description
This adjusts the horizontal and vertical position on the screen.
(1) For models other than SX7 Mark II: It can be executed when the projector is in both the remote mode and
power-on status at the same time.
For SX7 Mark II: It can be executed whenever the projector is in the power-on status.
(2) A “busy” response is given while the zoom or focus lens is being driven.
(Refer to the ZCONTDRV command and FCONTDRV command.)
(3) It may not be possible to execute the command with some input signals.
(4) This command has the same function as the buttons listed in the table below.
Model Menu
SX50
[Display settings] - [Input signal settings] - [Horizontal position]
[Display settings] - [Input signal settings] - [Vertical position]
SX6, SX60, X600, SX7, X700,
SX7 Mark II
[Display settings] - [Input signal settings] - [Horizontal position]
[Display settings] - [Input signal settings] - [Vertical position]
(5) The GET command can be used to retrieve the current horizontal and vertical position.
For details, refer to the GET command.
Example
Setting
> HPOS=12 This sets the horizontal position to 12.
< i:OK
Reference
> GET VPOS or ?VPOS This acquires the vertical position.
< g:VPOS=8
Obtain settable parameter range (Min, Max)
> RANGE HPOS
< r:HPOS=N, 0, 820 Any value from 0 to 820 can be set for the horizontal position.
* Commands are indicated by ">", and responses are indicated by "<".
Commands supported
This defines the environments that support the command (power supply state, input signal state).
SX50
01.00**
SX6
01.01**
SX60
01.01**
X600
01.01**
SX7
01.01**
X700
01.01**
SX7 Mark II
01.02**
O O O O O O O
Settin
g
Seitenansicht 53
1 2 ... 49 50 51 52 53 54 55 56 57 58 59 ... 243 244

Kommentare zu diesen Handbüchern

Keine Kommentare